MOHAWK VALLEY
HOME INSPECTIONS LLC
I
V
M

Servicing Fulton, Montgomery, Saratoga, Hamilton, Schenectady, and Albany Counties, NY
Here is a sample of the information we will cover in your
report.  The final report is a comprehensive home
inspection complete with individual notes which Meets and
often exceeds NACHI and ASHI standards of practice
General information

1 Report#: ____________________       Inspector:
______________________________       

2 Structures inspected:
__________________________________________________       

3 Type: 1 / 2 / 3 / 4 / Condo / Mfg / ____________       Age:/b> ________   
    

4 Owner: __________________________________________________   
    

5 Start: _______________       End: _______________       

6 Fee: ________       Payment method: Check / Cash / Invoiced / Escrow / ____________       

7 Present: Client / Owner / Tenant / Realtor / Builder / Contractor / ____________       


8 Occupied: Yes / No / No, but furnishings present / ____________       

9 Weather: Clear / Partly cloudy / Cloudy / Rain / Snow / Fog / ____________       

10 Temp: Cold / Cool / Warm / Hot / ____________       Ground: Wet / Damp / Dry / Frozen / ____________       

11 Front of structure faces: N / S / E / W / ____________       Entrance faces: N / S / E / W / ____________       

12 Foundation: Unfinished basement / Finished basement / Crawlspace / Slab / Post-pier / ____________       

13 Excluded: Septic / Security / Irrigation / Pool / Hot tub / Well / Shed / Playground / Sauna / Outdoor lighting /
Vacuum / Water filter / Water softener / Sound / Intercom / Generator / Sport court / Sea wall / Outbuildings /
____________       

14 Excluded: Furniture, stored items: Many | Some       Winterized       

15 Utilities not on: Natural gas | Propane | Water | Electricity | Oil       

16 General warnings: Gas leak       No CO alarms       Pre-1979       Abandoned oil tank   

Exterior

1 Footing material: Concrete / Masonry / Logs / None / Not visible / ____________       

2 Foundation material: Concrete / Concrete block / Post-pier / Brick / Stone / Steel on block (mfg homes) /
____________       

3 Wall structure: Wood frame / Steel frame / Concrete block / Pan Abode / Log / Brick / Stone / Straw bale /
____________       

4 Wall cover: Wood clapboard / Wood panels / Comp wood clapboard / Comp wood panels / Cement-based
clapboard / Cement-based panels / Wood shingles / Wood shakes / Vertical wood / Brick veneer / Stone veneer /
Stucco / EIFS / Metal / CAB / Vinyl / Masonite / ____________       

5 Driveway: Asphalt / Concrete / Aggregate / Gravel / Dirt / Permeable concrete / Porous pavers / Cobblestone /
None / N/A / ____________       

6 Sidewalk: Concrete / Aggregate / Paving stones / Gravel / Wood / Brick / None / N/A / ____________       

7 Exterior door material: SC Wood / SC Steel / SC Fiberglass / Sliding glass / Wood panel / Glass panel / HC Wood
/ ____________       

8 Excluded: Vegetation, stored items: Foundation and/or walls | Retaining walls       

9 Foundation: Cracks: Minor | Moderate | Major       Large tree near       Footing above grade       

10 Retaining walls: Missing or inadequate guardrails above       

11 Cracks or deterioration: Monitor, maintain | Repair-replace | Repair-replace w/ engineer       

12 Rotten timbers: Monitor | Repair-replace | Repair-replace w/ engineer       

13 Driveway: Minor cracks | Repair-replace | Trip hazard       Reseal asphalt       New gravel       

14 Drain: Missing | Inadequate | Clogged       

15 Sidewalks and patios: Minor cracks | Repair-replace | Trip hazard       

16 Undermined: Minor | Major, replace slabs       

17 Fences and gates: Repair-replace | Repair-replace (major)       Repair gates       

18 Soil contact: Soil w/in 6" of siding/trim | Soil w/in 6" of siding/trim, rot       Unlined wood planter boxes       

19 Rotten landscaping timbers: Replace | Replace steps       

20 Vegetation: <1' from exterior       Stump near exterior       Large tree, fall hazard       

21 Firewood contact       Trees against roof | Trees against roof with damage       

22 Drainage: Soggy yard or standing water       Negative perimeter slope: Soil | Pavement       

23 Downspouts: Loose or detached       Missing       Extensions missing or ineffective       

24 Dented, crushed, damaged       Terminate above roof surface       

25 Gutters: Missing       Damaged       Leaking       Poor slope       End caps missing       Rusted       

26 Crawlspace vents: Blocked       

27 Screens: Missing       Deteriorated       Clogged       Wells: Missing       Inadequate       

28 Siding: Gaps at penetrations       Deteriorated       Incomplete or missing       

29 Composition wood fiber: Minor, maintain | Moderate, maintain/replace | Major, replace       

30 Brick veneer: Minor cracks | Moderate cracks/deterioration | Major cracks/deterioration       

31 Cement-asbestos: Asbestos warning       Deteriorated       

32 Stucco: Repair-replace EIFS       Repair-replace stucco       

33 Logs: Uncaulked up-facing cracks       Rot       Sealant failed       Masonry contact       Bark       

34 Soffits: Deteriorated       Rot       Water stains: Dry | Wet       

35 Soffit vents: Screens missing or deteriorated       Screens painted or blocked       

36 Cantilever: No soffit cover | No insulation or soffit cover       Unvented soffit       

37 Fascia: Deteriorated       Rot       Rafter ends rotten       

38 Deck: Reseal deck | Reseal deck & rail       Repaint deck | Repaint deck & rail       Narrow spacing       

39 Substructure: Excluded       Needs bracing       Ledger board: No lag screws       No flashing       

40 Soil at support posts | Soil at support posts with rot       Inadequate clearance to soil below       

41 Stairs: Wobbly       Rot: Base of stringers | Treads       

42 Non-uniform risers: Warning | Repair       Non-standard: Warning | Repair       

43 Hand rails: Missing       Ungraspable       Loose       Not continuous or too short       

44 Guardrails: Wide gaps       Missing       Wobbly       Low       Climbable       

45 Electrical: Cover plates: Missing | Broken       

46 Receptacles: Open ground, rewire or replace with 2-prong | Open ground, rewire       

47 Broken       Scorched       Hot-neutral reverse       Loose       No power       Worn       

48 Damaged waterproof cover | Not waterproof | Need in-use cover       

49 GFCI receptacles: Won't trip | Won't trip with tester       Won't reset       Energized when tripped       

50 Non-GFCI outside within 6'-6" of ground       Damaged by paint       Bad GFCI, can't verify others       

51 Light fixtures: Inoperable       No bulb(s)       Loose or substandard       Deteriorated       

52 Not rated for use in wet location       No caulk around back plate       

53 Wiring: Exposed       Not terminated       Splices not in box       Extension cord       Lamp cord       

54 Wires run overhead to trees       

55 Exposed wiring at disconnect switch: Install lock | Repair (emergency disconnect)       

56 Paint & caulk: Caulk missing or deteriorated       Paint or stain failing: Entire | Some areas       

57 Window glazing putty missing or deteriorated       Caulked head flashing       

58 Hose bibbs: No anti-siphon       No water       No handle       Need screws       Leaks       Winterized       

59 Supply pipes outside subject to freezing       

60 Vents: Vent caps: Deteriorated       Missing       

61 Plumbing vents: <3' above opening | <10' from opening       

62 Direct vent: Inadequate clearance to openings or ignition sources       Installed upside down       

63 Propane tank: <3' from opening | <3' from electric meter | <10' from ignition source       

64 250/500 gal. tank <10' | 1000 gal. tank <25' | Underground 1000 gal. tank <10'       

65 Hornet, bee or wasp nest       


Roof

1 Roof inspection method: Traversed / From eaves / From ground / From windows / Not inspected / ____________
      

2 Roof type: Gable / Cross-gable / Hipped / Cross-hipped / Pyramidal / Shed / Flat / Mansard / Gambrel / A-frame /
____________       

3 Roof covering: Composition / Wood shakes / Torch down / Built up / Metal / Concrete tile / Clay tile / Slate / EPDM
/ Rolled / ____________       

4 Estimated age of roof: ____________________       

5 Gutter & downspout material: Aluminum / Steel / Plastic / Copper / Galvanized / Wood / Built-in / None /
____________       

6 Roof ventilation: Adequate / Inadequate / None visible / Unable to determine / ____________       

7 Excluded: Couldn't traverse       

8 Snow obscures: Partially | Completely       Debris obscures: Partially | Completely       

9 Vegitation and maintenance: Clean gutters       Clean roof       Moss       Trees overhanging       

10 Trees against roof | Trees against roof with damage       

11 Age: Beyond service life       < 5 yrs left       

12 New composition roof will need: Tear-off | Sheathing | Both       

13 Flashing: Deteriorated, rusted       Lead improper at top of vent pipes       

14 At chimney: Deteriorated, substandard       No counterflashing       

15 Rubber boots: Deteriorated       Lifting or improperly installed       

16 Roof design: Slope-slope | Slope-wall | Slope-flat       No cricket above wide chimney       

17 Siding in contact with shingles below       

18 Composition: Deteriorated or missing       Popped nails       Raised shingles       Pressure washed       

19 < 3/12 slope       Pabco HO25       

20 Shakes: Deteriorated | Clean and preserve | Both       

21 Metal: Dented or damaged       Failing paint       Rust       Asphalt or tar sealant       

22 Concrete or tile: Chipped or cracked       Slipped       Missing       

23pan> Flat roof: Coating failed       Ponding       Gaps: Seams | Penetrations | Both       

24 Parapet walls: Deteriorated, substandard flashing | Slopes towards exterior       

25 Masonite Woodruf: Warning | Repair-replace       

26 Vents: Improper B-vent termination       

27 Plumbing vent: <6" above surface | <12" from vert. surface       Blocked: Caps | Debris       

Garage

1 Excluded: Stored items: Perimeter | Perimeter and center | Vehicle door(s) | All       

2 Appliances with no protective barrier       Walls or ceiling not fire-rated       

3 Garage-house door: Not fire-rated | Pet door       No auto-close | Repair/replace auto-close       

4 Weatherstrip: Missing | Deteriorated | Both       Gaps around when closed       

5 Vehicle door: Replace | Repair/replace       Water stains - caulk, paint       Lock inoperable or difficult       

6 Not balanced       Broken spring       No restraining cable on springs       Difficult to open or close       

7 Weatherstrip: Missing | Deteriorated | Both       

8 Vehicle door opener: Inoperable       Mechanical auto-reverse inoperable or needs adjustment       

9 Lock not disabled       Infrared photo eyes: Too high | Inoperable | None       

10 Control button: Too low or within reach of children | Loose       

11 Entry door: Deteriorated entry       Weatherstrip missing or deteriorated       Hollow core       

12 Attic access: Hatch missing | Hatch not fire-rated       Pull-down stairs not fire-rated       

13 Stairs: Wobbly       Garage-house step missing       

14 Non-uniform risers: Warning | Repair       Non-standard: Warning | Repair       

15 Handrails: Missing       Ungraspable       Loose       Not continuous or too short       

16 Guardrails: Wide gaps       Missing       Wobbly       Low       Climbable       

17 Electrical: Cover plates: Missing | Broken       

18 Receptacles: Open ground, rewire or replace with 2-prong | Open ground, rewire       

19 Broken       Scorched       Hot-neutral reverse       Loose       No power       Worn       

20 GFCI receptacles: Won't trip | Won't trip with tester       Won't reset       Energized when tripped       

21 Non-GFCI in garage (excluding 1 for freezer)       Damaged by paint       Bad GFCI, can't verify others       

22 Wiring: Exposed       Not terminated       Splices not in box       Loose       Extension cord       Lamp cord       

23 Rodent evidence: Light to moderate | Heavy       

Attic

1 Inspection method: Viewed from hatch / Traversed / Partially traversed / Not inspected / ____________       

2 Roof structure: Trusses / Rafters / Not visible / ____________       

3 Ceiling structure: Trusses / Ceiling beams / Not visible / ____________       

4 Insulation material: Fiberglass loose / Fiberglass roll/batt / Mineral wool loose / Mineral wool roll/batt / Cellulose
loose / Cellulose roll/batt / Vermiculite / None / ____________       

5 Insulation depth: _______________       Estimated R value: ____________________       

6 Excluded: No attic | No access hatch | Hatch inaccessible | Some areas inaccessible       

7 <1" clearance to flue       Water stains on wood: Dry | Wet       

8 Ceiling insulation: Vermiculite, asbestos warning       Paper facing on batts exposed       

9 Substandard | Uneven | Missing in some areas | None | None at skylight       

10 In contect with recessed lighting: Not IC rated | No visible rating       

11 Exhaust fans: No duct | Duct broken or collapsed | No vent cap       

12 Access hatch: No insulation over | No weatherstrip       Uninsulated pull-down stairs       

13 Electrical: Cover plates: Missing | Broken       

14 Wiring: Not terminated       Splices not in box       Loose       Extension cord       Lamp cord       

15 Attic fan: Inoperable | Noisy, vibration       

16 Vents: Blocked | Screens deteriorated or missing       Inadequate ventilation       

17 Water pipe insulation: None | Repair       

18 Rodent evidence: Light to moderate | Heavy       

19 Hornet, bee or wasp nest      


Electric service

1 Service type: Underground / Overhead / ____________       

2 Protection: Breakers / Fuses / ____________       

3 Amperage: 60 / 100 / 125 / 150 / 200 / 400 / ____________       Upgrade to 200 amp service       

4 Voltage: 120 / 120/240 / 3 phase, 4 wire, 120/208 / ____________       

5 Location of main service switch: ________________________________________       

6 Location of sub panels: ________________________________________       

7 Location of main disconnect: Top / Bottom / Top bank / All / ____________       

8 Service entrance conductor material: Aluminum / Copper / Copper-clad aluminum / ____________       

9 System ground: Ground rod / Cold water / Concrete encased electrode / Copper / Rebar / ____________       

10 Main disconnect rating: 60 / 100 / 125 / 150 / 200 / N/A / ____________       

11 Branch circuit wiring type: NM sheathed / BX / Knob and tube / Copper / Aluminum multi-strand / Aluminum
solid-strand / ____________       

12 Aluminum wiring present: No / Yes / Can't verify / ____________       

13 Smoke detectors: Yes / No / ____________       

14 Excluded: Interior low voltage lighting       

15 Panel cover not removed: Stored items, debris       Paint/wallpaper       Arcing noises       

16 Shelving, cabinets or structure       Equipment energized       Water: On floor | Leaking into panel       

17 Service drop wires: Frayed       In trees       

18 < 10' above ground | < 12' above driveway | < 3' from openings       

19 <3' above 3/12 roof or steeper | <8' above a flat roof | <18" above roof ridge       

20 Service entrance wires: Frayed       Loose point of attachment       

21 Drip loop: None       Substandard       

22 Service mast: Loose       Bent       Broken or damaged       

23 Meter: Missing or broken seal       Tap before meter       

24 Federal Pacific       Zinsco panel | Zinsco breakers       

25 Service panel (substitute "sub panel" as needed): Inadequate working space       

26 Missing or inadequate legend       Tap before main       >6 switches or hand movements       

27 Bushing missing       Undersized wire       Wires not terminated       Contamination       

28 Double or multi tap       Doubled or bundled neutrals       Open knockout       

29 Burned or melted wires or insulation       No anti-oxidant       Old fuses: Eval | Replace       

30 Burned or damaged circuit breaker       

31 GFCI breaker: Won't trip       Won't reset       

32 AFCI breaker: Won't trip       Won't reset       Recalled (blue test button)       

33 Service panel cover: None or not installed       Not flush       Open closure       

34 Screws: Missing       Pointed or too-long       In contact with conductors       

35 Grounding and bonding: Plastic pipe       Dielectric connectors       

36 Clamp on rod: Missing | Loose | Rusted or corroded       

37 Clamp on pipe: Missing | Loose | Rusted or corroded       

38 Sub panel: Neutrals and grounds bonded at sub-panel       

39 Branch circuit wiring: Aluminum solid strand       Knob and tube: Energized | Abandoned       

40 Incompatible components: Undersized: Meter base | Service conductor | Main service panel       


Water heater

1 Estimated age: ____________________       Type: Tank / Instantaneous / ____________       

2 Energy source: Electricity / Natural gas / Propane / Oil / ____________       

3 Capacity: 30 / 40 / 47 / 50 / 52 / 65 / 66 / 80 / Not visible / ____________       

4 Manufacturer: American / American Proline / American Standard / A.O. Smith / AquaStar / Bosch / Bradford White
/ Envi-Ro-Temp / General Electric / Hotpoint / Reliance / Rheem / Richmond / Row Con / Rudd / State / Takagi /
U.S. Craftmaster / Vanguard / Whirlpool / ____________       

5 Model: ________________________________________       

6 Water temperature: ____________________       

7 Excluded: Shut off       

8 Obscured by: Insulated jacket | Stored items | Permanent enclosure       

9 Temp > 120       Flame or source of spark <18" from garage floor       Reverse plumbed       

10 Undersized       No catch pan or drain       Circulation pump installed       

11 Age: Near 8-12 years | 8-12 years or older | Unknown, may be old       

12 Corrosion: On tank | Water stains below | Both       On fittings       

13 Earthquake straps: Missing | Substandard       

14 Supply valve: Missing | Handle missing       

15 T-P valve: Missing | Leaking       

16 Drain line: Missing       Routed up       >6" from floor       <6" from floor       Undersized       In crawlspace       >4
elbows       

17 Electric: Substandard wiring       No insulated pad       

18 Gas: Inadequate combustion air       Melted insulation by draft hood       

19 No drip leg       Scorch marks       Scale on burner, pilot assemblies or at draft hood       

20 Flame: Yellow | Noisy (whistling) | Floats | Too high       

21 Flame sheild missing or loose: Inner | Outer | Both       


Heating and cooling

1 Estimated age: ____________________       

2 Primary heat energy source: Natural gas / Electric / Oil / Wood / Propane / Solar / Coal / ____________       

3 Primary heat type: Forced air / Heat pump / Baseboard / Fan wall units / Radiant / Hot water / Gravity / Circulating
pump / Steam / Up draft / Down draft / Horz draft / Standard / Medium / High / Gas fireplace/stove / ____________   
    

4 Primary A/C energy source: Electric / Natural Gas / Propane / N/A / ____________       

5 Primary A/C type: Split system / Heat pump / N/A / ____________       

6 Distribution: Sheet metal / Flex / Metal pipe / Plastic pipe / Not visible / N/A / ____________       

7 Manufacturer: Amana / American Standard / Armstrong / Bryant / Carrier / Coleman / General Electric / Goodman
/ Heil / Intertherm / Janitrol / Lennox / Luxaire / Payne / Rheem / Ruud / Tempstar / Thermopride / Trane / York /
____________       

8 Model: ________________________________________       

9 Filter location: Return air above / Return air below / Behind grill / Base of furnace / Top of furnace /
____________       

10 Last service date: ____________________       

11 Excluded: <60 degrees, can't eval A/C       Can't verify heat source in every room       

12 No response: Furnace | Boiler | Heat pump | A/C       

13 Shut off: Furnace | Boiler | Heat pump | A/C condensing unit       

14 Age: Furnace: Near 15-20 years | 15-20 years or older | Unknown, may be old       

15 Heat pump condensing unit: Near 15-20 years | 15-20 years or older | Unknown, may be old       

16 A/C condensing unit: Near 8-15 years | Older than 8-15 years | Unknown, may be old       

17 Service: Now & annually (heat pump or AC)       Now & annually (gas or oil)       Now & annually (hydronic)       

18 Now & every few years       Perform heat exchanger CO test       

19 Return air: Open in basement - gas & oil       Gaps in attached garage       No gaps below interior doors       

20 Fresh air: Fresh air timer not set       Keep air supply ports open 24-7       

21 Filters: Replace now | Wash now | Maintain in future       

22 Deteriorated | Not secure | Wrong size | None       

23 Ducts: Broken or disconnected       Broken hangers       Lying on ground       

24 Flex duct: Sagging | Supports > 5' apart | Narrow support straps | All       

25 Asbestos on ducts: Warning | Deteriorated       

26 Ducts need cleaning: Debris, dirt, dust | Rodents | Mold | New construction       

27 Insulation: None | Deteriorated       

28 Combustion air, clearances and disconnect: Inadequate combustion/dilution air       

29 Flame or spark <18" above floor in garage       <1" from B-vent flue       <2" from double wall flue       

30 Single wall flue: <18" w/o draft hood       <9" w/ draft hood and oil       <6" w/ draft hood and gas       

31 Cabinet: <6" from top or sides of furnace/boiler       <24" from front of oil furnace/boiler       

32 <18" from front of gas/electric furnace or boiler       

33 Gas: Rusted or cracked heat exchanger       No drip leg       

34 Gas supply lines: Rust       Flexible connector: Through cabinet | Subject to damage       

35 Flame: Yellow/orange | Floating | Noisy or dancing | Pop | Rollout | Changes with fan on       

36 Oil: Flame not orange to yellow-white, or sooty       Oil smell or soot       

37 Oil tank: Buy replacement insurance       Leaking | Rust       

38 Buy contamination & clean up insurance (for tanks still in use in WA state only)       

39 Oil supply lines: Leaking       Subject to damage       No shut-off valve       No filter       

40 Barometric draft damper: Defective       Spilling exhaust gases       

41 Air handler: Noise or vibration       Loose v-belt       No catch pan in attic - heat pump or A/C       

42 Evaporator coils: Ice       Cooling fins: Deteriorated | Dirty | Both       

43 Outside condensing unit: Not level       Noise or vibration       No disconnect       

44 Refrigerant line insulation deteriorated or missing       Cooling fins: Deteriorated | Dirty | Both       

45 Inadequate clearance: Vegetation | Structure       

46 A/C supply air: Not cool enough | Too cool       

47 Hydronic: Open system, Legionnaire's disease       


Plumbing and laundry

1 Water pressure: ____________________       

2 Location of main water shut-off: ________________________________________       

3 Location of main water meter: ________________________________________       

4 Location of main fuel shut-off: ________________________________________       

5 Visible fuel storage systems: ________________________________________       

6 Type: Public / Private / Community well / ____________       

7 Service pipe: Copper / Galvanized / PE / Lead / Not visible / ____________       

8 Supply pipe: Copper / Galvanized / CPVC / PE / Polybutylene / Not visible / ____________       

9/span> Vent pipe: Plastic / Galvanized / Cast iron / Copper / Not visible / ____________       

10 Drain pipe: Plastic / Galvanized / Cast iron / Copper / Not visible / ____________       

11 Waste pipe: Plastic / Galvanized / Cast iron / Copper / Not visible / ____________       

12 Excluded: Laundry appliances       Washer had clothes in it       

13 Main shut-off not found       Meter not found       Inspect, pump septic       

14 Pre-1986 lead solder warning       Lead service pipe       Polybutylene       

15 Public supply pressure: > 80 psi | < 40 psi, warn | < 40 psi, repair       Need expansion tank       

16 Galvanized steel supply: Old, advise, monitor | Corrosion, leaks or low flow       

17 Copper supply: Pin holes or corrosion       Steel hangers       

18 Drain and waste: Active leak       Stains: Monitor | Repair       

19 Oakum packing deteriorated or missing       Hanger straps: Broken | Substandard       

20 Waste cleanout: Cap missing       Bad seal       Shows wear: Public sewer | Private septic       

21 Laundry: No catch pan or drain for washer | No visible drain       Fan timer not set       

22 Laundry sink: Unanchored       Concrete cracked | Concrete cracked and leaking       

23 Dryer duct: Plastic or foil       Kinked       Broken or disconnected       None       

24 Needs cleaning       Too long       Routed vertically       Sheet metal screws       

25 Water softener discharge: To septic system       To sump pump       Near foundation       

26 Air gap: None or substandard       Inaccessible       

27 Sump pump: Installed       Inoperable       Couldn't test       No GFCI       Not on dedicated circuit       

28 No check valve       No pit liner     


Fireplaces, woodstoves and chimneys

1 Fireplace type: Masonry / Masonry with metal liner / Metal prefab / ____________       

2 Woodstove type: Metal / Metal insert / Ceramic / ____________       

3 Chimney type: Masonry / Metal / ____________       

4 Excluded: Fireplace firebox obscured by ashes or debris       

5 Gas: No gas | No response | No controls found       

6 Hearth: <18" deep | Deteriorated       

7 Clean flue: Annually for all       Now: Fireplace | Woodstove       

8 Fireplace: Rusted liner       Gaps between firebox and face       

9 Fireplace firebrick: Minor cracks | Repair, replace       

10 Refractory panels: Repair | Replace       

11 Damper: Stuck open or closed       Deteriorated       Missing       

12 Woodstove: In garage       Replace firebrick       Eval and verify safe installation       

13 Inadequate clearances: Flue pipe | Stove | Heat shield       

14 Chimney: Missing: Screen | Rainproof cover | Both       

15 Too short       Pie plate       Wood burning flue shared with oil or gas flue       

16 Repoint mortar       Crown deteriorated       Cracked flue tiles       Major masonry repairs       

17 Unlined wood burning | Unlined with gas appliance | Unlined with oil furnace       

18 Gas: Vent-free warning       Glass: Fogged | Soot       

19 Conversion: Damper can close       No glass doors       

Crawl space

1 Inspection method: Traversed / Partially traversed / Viewed from hatch / Not inspected / ____________       

2 Insulation material: Fiberglass roll/batt / None / ____________       

3 Pier/support post material: Wood / Bearing wall / Concrete / Masonry / Steel / ____________       

4 Beam material: Solid wood / Built up wood / Laminated wood / Steel / ____________       

5 Floor structure above: Wood joists / Engineered wood joists / Wood trusses / 2x6 T&G / Not visible /
____________       

6 Vapor barrier present: Yes / No / Not visible / ____________       

7 Excluded: Some areas inaccessible       

8 Structural: Post-beam missing ties       Undermined footing       Overspanned: Joists | Beams       

9 Joist notches and bored holes: Joists, various substandard       

10 Notches: In middle 1/3 | >1/6 of depth | >1/4 of depth at end       

11 Bored holes: <2" from edge | >1/3 of depth       

12 Venting: None or substandard       Blocked       

13 Water: Standing water | Past water intrusion       

14 Vapor barrier: Repair | Replace | None | None in some areas       

15 Floor insulation: Repair | None | None in some areas       Paper facing on batts exposed       

16 Water pipe insulation: None | Repair       

17 Cellulose: Paper footing forms       Cellulose debris       Stored items       

18 Wood-soil: At support posts       Rotten support posts       Inadequate clearance to soil below       

19 Electrical: Cover plates: Missing | Broken       

20 Wiring: Not terminated       Splices not in box       Loose       Extension cord       Lamp cord       

21 Rodent evidence: Light to moderate | Heavy       

22 Hornet, bee or wasp nest       

Basement

1 Insulation material: Fiberglass roll/batt / None / ____________       

2 Pier/support post material: Wood / Bearing wall / Concrete / Masonry / Steel / ____________       

3 Beam material: Solid wood / Built up wood / Laminated wood / Steel / ____________       

4 Floor structure above: Wood joists / Engineered wood joists / Wood trusses / 2x6 T&G / Not visible /
____________       

5 Structural: Post-beam missing ties       Overspanned: Joists | Beams       

6 Notches and bored holes: Joists, various substandard | Studs, various substandard       

7 Joist notches: In middle 1/3 | >1/6 of depth | >1/4 of depth at end       

8 Joist bored holes: <2" from edge | >1/3 of depth       

9 Stud notches: >40% of depth | >25% of depth, bearing wall       

10 Stud bored holes: Bored hole <5/8" from edge | >60% of depth | >40% of depth, bearing wall       

11 Water: Standing water or wet areas | Past water intrusion       

12 Entry door: Deteriorated entry       Repair/replace lockset       

13 Weatherstrip: Weatherstrip missing or deteriorated | Replace       

14 Stairs: Wobbly       

15 Non-uniform risers: Warning | Repair       Non-standard: Warning | Repair       

16 Hand rails: Missing       Ungraspable       Loose       Not continuous or too short       

17 Guardrails: Wide gaps       Missing       Wobbly       Low       Climbable       

18 Electrical: Cover plates: Missing | Broken       

19 Receptacles: Open ground, rewire or replace with 2-prong | Open ground, rewire       

20 Broken       Scorched       Hot-neutral reverse       Loose       No power       Worn       

21 GFCI receptacles: Won't trip | Won't trip with tester       Won't reset       Energized when tripped       

22 Damaged by paint       

23 Wiring: Exposed       Not terminated       Splices not in box       Loose       Extension cord       Lamp cord       

24 Rodent evidence: Light to moderate | Heavy       

Well

1 Location of well equipment: ________________________________________       

2 Location of tank shut off valve: ________________________________________       

3 Age: Pump: Near 15-20 years | 15-20 years or older       

4 Steel pressure tank: Near 15-25 years | 15-25 years or older       

5 Test well water       Pressure <40 psi       Sediment or murky       Unused or abandoned well       

6 Well casing: <12" high       In depression       Near: Downspout | Sump pump discharge       

7 <50' from septic field       <30' from house       

8 Well equipment: Rust or corrosion | Leaking | Both       

9 Pressure gauge: Broken | Missing       

10 Pressure tank: Rust or corrosion       Cycles quickly | Sounds waterlogged       

11 Electrical: Cover plates: Missing | Broken       

12 Wiring: Exposed       Splices not in box       

Kitchen

1 Appliances older than 10 or 15 years       

2 Dishwasher: Inoperable       No water       No high loop or air gap | No air gap       

3 Loose or missing bracket       Water beneath       Noisy       Kick plate missing, loose or deteriorated       

4 Bad door seal       Door handle loose or missing       Leaking at air gap       

5 Refrigerator: Inoperable       Ice maker turned off       No ice or water       

6 Bad door seal       Broken or missing shelving       Door handle(s) loose or missing       Uses GFCI       

7 Range hood: None       Light: Light inoperable | Missing bulb(s)       

8 Fan: Inoperable       Noisy       Vents indoors       Filter(s) missing       Undersized exhaust duct       

9 Microwave: Inoperable       Turntable inoperable       No turntable       Digital display defective       

10 Range/Oven/Stove top: Inoperable: Bake | Broil | Burner(s) | Oven light       

11 No anti-tip bracket       Knob(s) missing or damaged       Door handle(s) loose or missing       

12 Bake element standoffs missing or damaged       Downdraft exhaust: Inoperable | Noisy       

13 Food disposal: Inoperable       Noisy       Substandard wiring       Corroded or at end of life       

14 Hot water dispenser: Inoperable       Disconnected       

15 Electrical: Cover plates: Missing | Broken       

16 Receptacles: Open ground, rewire or replace with 2-prong | Open ground, rewire       

17 Broken       Scorched       Hot-neutral reverse       Loose       No power       Worn       

18 GFCI receptacles: Won't trip | Won't trip with tester       Won't reset       Energized when tripped       

19 Non-GFCI within 6' of sink       Damaged by paint       Bad GFCI, can't verify others       

20 Light fixtures: Inoperable       No bulb(s)       Loose or substandard       Deteriorated       

21 Closet lighting: Open lamp       Incandescent <12" clearance | Fluorescent <6" clearance       

22 Exhaust fans: Inoperable or inadequate       Noisy       

23 Plumbing: Shut-off valve handle missing       Supply line leak       

24 Faucets: Loose or missing handle       Leaks when off       Leaks when on       Reverse plumbed       

25 Sinks: Sprayer inoperable or defective       Enamel deteriorated       

26 Sink drains: Leak       Clogged or drains slowly       Substandard repair       Flexible pipe       

27 No trap       S-trap       

28 Cabinets: Deteriorated       Loose       Missing shelving or components       

29 Hardware loose and/or missing       Drawers difficult to operate       No pulls or handles       

30 Water damage below sink: Minor | Needs repair       

31 Countertops: Minor deterioration       Deteriorated       Loose laminate       

32 Needs caulk at backsplash       Cracked or broken concrete       

33 Tile, stone and grout: Deteriorated       Reseal grout       

34 Floors: Refinish wood floor       Gaps between tiles in wet areas       

35 Vinyl: Deteriorated | Deteriorated in wet areas       

36 Tile, stone and grout: Deteriorated | Deteriorated in wet areas       Reseal grout       

Bathrooms

1 Electrical: Switch within reach of shower       Cover plates: Missing | Broken       

2 Receptacles:u> Open ground, rewire or replace with 2-prong | Open ground, rewire       

3 Broken       Scorched       Hot-neutral reverse       Loose       No power       Worn       

4 GFCI receptacles: Won't trip | Won't trip with tester       Won't reset       Energized when tripped       

5 Non-GFCI within 6' of sink       Damaged by paint       Bad GFCI, can't verify others       

6 Light fixtures: Inoperable       No bulb(s)       Loose or substandard       Deteriorated       

7 Closet lighting: Open lamp       Incandescent <12" clearance | Fluorescent <6" clearance       

8 Exhaust fans: None with shower       Inoperable or inadequate       Noisy       

9 Plumbing: Shut-off valve handle missing       Supply line leak       

10 Faucets: Loose or missing handle       Leaks when off       Leaks when on       Reverse plumbed       

11 Sinks: Enamel deteriorated       Cracked or broken       Loose       Stopper missing or defective       

12 Sink drains: Leak       Clogged or drains slowly       Substandard repair       Flexible pipe       

13 No trap       S-trap       

14 Toilets: No water       Loose | Loose w/ wet or damaged floor       Clogged or weak flush       

15 Runs       Flapper valve did not reseat       Cracked or broken: Bowl | Tank | Tank lid | All       

16 Bathtubs: Enamel deteriorated       Clogged or drains slowly       Tile or grout deteriorated       

17 Caulk missing or deteriorated: At floor | At surround | At base of spout | All       

18 Jetted tub GFCI: None visible | No access, cannot verify       

19 Showers: Clogged or drains slowly       Tile or grout deteriorated       Diverter valve defective       

20 Caulk missing or deteriorated: At floor | Around surround | All       

21 Cabinets: Deteriorated       Loose       Missing shelving or components       

22 Hardware loose and/or missing       Drawers difficult to operate       No pulls or handles       

23 Water damage below sink: Minor | Needs repair       

24 Countertops: Minor deterioration       Deteriorated       Loose laminate       

25 Needs caulk at backsplash       Cracked or broken concrete       

26 Tile, stone and grout: Deteriorated       Reseal grout       

27 Floors: Refinish wood floor       Gaps between tiles in wet areas       

28 Vinyl: Deteriorated | Deteriorated in wet areas       

29 Tile, stone and grout: Deteriorated | Deteriorated in wet areas       Reseal grout       

Interior rooms

1 Heating and cooling: No visible source of heat       

2 Recalled Cadet heaters, FW, FX, LX, TK, ZA, Z, RA, RK, RLX, RX, RW, ZC       

3 Registers: Missing       Loose or not flush       Damaged       Weak flow or no flow       

4 Baseboard heaters: Baseboard heater deteriorated       Electric receptacles above       

5 Electrical: Doorbell: Inoperable       Button loose or damaged       

6 Smoke alarms: None       >10 years old       Replace batteries       Too few | Damaged or missing | Both       

7 Cover plates: Missing | Broken       

8 Receptacles: Open ground, rewire or replace with 2-prong | Open ground, rewire       

9 Broken       Scorched       Hot-neutral reverse       Loose       No power       Worn       Childproof caps       

10 Few receptacles | 2-pronged receptacles | Few & 2-pronged receptacles       

11 GFCI receptacles: Won't trip | Won't trip with tester       Won't reset       Energized when tripped       

12 Non-GFCI within 6' of sink       Damaged by paint       Bad GFCI, can't verify others       

13 Light fixtures: Inoperable       No bulb(s)       Loose or substandard       Deteriorated       

14 Old fixtures       Need 3-way switches at both ends: Hall | Stairs       

15 Closet lighting: Open lamp       Incandescent <12" clearance | Fluorescent <6" clearance       

16 Wiring: Exposed       Not terminated       Splices not in box       Extension cord       Lamp cord       

17 Fans: Whole-house fan: Inoperable       Noisy       

18 Ceiling fans: Inoperable       Wobbly, unbalanced       <7' from floor       

19 Ceiling: Minor cracks       Dry stains, monitor       Wet stains: Roof leak | Plumbing leak       

20 Pre-1979 asbestos popcorn: Intact, warn | Deteriorated, needs repair or abatement       

21 Walls: Minor cracks       

22 Windows: Won't open       Lock missing or inoperable       Springs broken       Vents closed       

23 Glass: Broken       Double pane seal(s) failed       Non-tempered w/in 18" of floor       

24 Screens: Missing       Holes or tears       

25 Bedroom egress: Too high | Won't open, or opening too small | Both       

26 Doors: Deteriorated interior       Won't latch       Binds in jamb       No gap for return air       

27 Keyed lock or deadbolt on interior door       

28 Locksets: Missing       Loose       Damaged       Installed backwards       

29 Entry door: Deteriorated entry       Weatherstrip missing or deteriorated       Hollow core       

30 Deadbolt: Key-only, no handle       Inoperable or difficult       

31 Sliding glass doors: Deteriorated       Difficult to open/close       Lock inoperable or difficult       

32 Double pane seal(s) failed       Handle missing or loose       

33 Sliding screen doors: None for only source of ventilation       Deteriorated       

34 Holes or tears       Difficult to open/close       

35 Stairs: Door swings out over stairs       

36 Non-uniform risers: Warning | Repair       Non-standard: Warning | Repair       

37 Handrails: Missing       Ungraspable       Loose       Not continuous or too short       

38 Guardrails: Wide gaps       Missing       Wobbly       Low       Climbable       

39 Floors: Not level       Refinish wood floor       Squeaky       

40 Vinyl: Deteriorated | Deteriorated in wet areas       

41 Gaps between tiles in wet areas       

42 Carpet: Loose | Loose with trip hazard       Needs cleaning       Deteriorated       

43 Tile, stone and grout: Deteriorated | Deteriorated in wet areas       Reseal grout       

44 Miscellaneous:

45 Trim: Missing | Damaged | Both       

46 Fixtures: Missing | Damaged | Both       

47 Rodent evidence: Light to moderate | Heavy       

48 Lead paint: Intact | Poor condition